| Description |
Never attempt to measure the circuit resistance of the airbag
module (squib) even if you are using a specified tester. If the circuit
resistance is measured with a tester, accidental airbag deployment will
result in serious personal injury. |
Removal 1. Disconnect the battery negative cable and wait for at least three minutes before beginning work. 2. Remove the crash pad. (Refer to Body - "Crash Pad" ) 3.
Component Location Components 1. Seal2. Intake Duct Case3. Intake Door4. Intake Actuator5. Intake Duct Case (A)6. Climate Control Air Filter7. Climate Control Air Filter Cover8. Cluster Ionizer9. Blower Upper Case10. Blower Lower Case11. Power Mosfet12.
Inspection 1. Turn the ignition switch OFF. 2. Disconnect the intake actuator connector. 3. Verify that the intake actuator operates to the fresh position when connecting 12V to terminal 3 and grounding terminal 4. Verify that the intake actuator operates to the recirculation position when connected in reverse.