Fuse Inspection 1. Check that the fuse holders are loosely held and that the fuses are securely fixed by the holders. 2. Check that each fuse circuit has the exact fuse capacity.
Components Connector Pin Information No.DescriptionNo.Description1-21-2Illumination output22-3Rheostat down switch234P output4Rheostat up switch24Immobilizer5AT N output25AT S output6Oil pressure26AT R output7Low washer27AT P output8Charge28-9AT D output29-10Illumination +30MM_CAN High11-31MM_CAN Low12Active ECO32C_CAN High13Heated wheel indicator33C_CAN Low14Fuel34Trip switch115Detent output35Trip switch216Fuel ground36Trip switch ground17-37Signal ground18Speaker -38-19Speaker +39IGN +20Aig bag +40Battery +
Component Location Components 1. Seal2. Intake Duct Case3. Intake Door4. Intake Actuator5. Intake Duct Case (A)6. Climate Control Air Filter7. Climate Control Air Filter Cover8. Cluster Ionizer9. Blower Upper Case10. Blower Lower Case11. Power Mosfet12.
Inspection 1. Turn the ignition switch ON. 2. Manually operate the control switch and control the voltage of the blower motor. 3. Select the control switch to raise the voltage until high speed. Specification Fan Speed (Manual)Motor Voltage (V)13.