| Troubleshooting |
| Problem Symptoms Table |
| Symptom | Suspected Area |
| No blower operation | 1. Blower fuse |
| 2. Blower relay | |
| 3. Blower motor | |
| 4. Power mosfet | |
| 5. Blower speed control switch | |
| 6. Wire harness | |
| No air temperature control | 1. Engine coolant capacity |
| 2. Heater control assembly | |
| No compressor operation | 1. Refrigerant capacity |
| 2. A/C fuse | |
| 3. Compressor | |
| 4. A/C pressure transducer | |
| 5. A/C switch | |
| 6. Evaporator temperature sensor | |
| 7. Wire harness | |
| Vented air not cold | 1. Refrigerant capacity |
| 2. Refrigerant pressure | |
| 3. Drive belt | |
| 4. Compressor | |
| 5. A/C pressure transducer | |
| 6. Evaporator temperature sensor | |
| 7. A/C switch | |
| 8. Heater control assembly | |
| 9. Wire harness | |
| Insufficient cooling | 1. Refrigerant capacity |
| 2. Drive belt | |
| 3. Compressor | |
| 4. Condenser | |
| 5. Expansion valve | |
| 6. Evaporator | |
| 7. Refrigerant lines | |
| 8. A/C pressure transducer | |
| 9. Heater control assembly | |
| No engine idle-up when A/C switch is ON | 1. Engine ECM |
| 2. Wire harness | |
| No air inlet control | 1. Heater control assembly |
| No mode control | 1. Heater control assembly |
| 2. Mode actuator | |
| No cooling fan operation | 1. Cooling fan fuse |
| 2. Fan motor | |
| 3. Engine ECM | |
| 4. Wire harness |
Specification Air Conditioner ItemSpecificationCompressorType7VSX18Oil type & CapacityPAG 120
Component Location Components 1. Seal2. Intake Duct Case3. Intake Door4. Intake Actuator5. Intake Duct Case (A)6. Climate Control Air Filter7. Climate Control Air Filter Cover8. Cluster Ionizer9. Blower Upper Case10. Blower Lower Case11. Power Mosfet12.
Inspection 1. Turn the ignition switch OFF. 2. Disconnect the intake actuator connector. 3. Verify that the intake actuator operates to the fresh position when connecting 12V to terminal 3 and grounding terminal 4. Verify that the intake actuator operates to the recirculation position when connected in reverse.