| Lubricant |
| Item | Defined lubricant | Capacity |
| Transfer oil | Oil for the transfer case only Ultra low viscosity of ATF SHELL TF0870 | 0.620L (0.165 U.S gal., 0.66 U.S.qt., 0.55 Imp.qt.) |
Removal In case of replacing the controller (ECU) and transfer case due to changing characteristics of the frictional materials inside the transfer case, it is necessary to check and enter the calibration data.
Inspection Prohibition on checking, refilling and replacing the transfer case oil - Do not check, refill and replace the transfer case oil because the oil for the transfer case only (ultra-low viscosity of ATF SHELL TF 0870) is filled when coming out of the factory.
Description The ambient temperature sensor is located inside the side mirror and detects ambient air temperature. It is a negative type thermistor; resistance will increase with lower temperature, and decrease with higher temperature. The sensor output will be used for discharge temperature control, temperature regulation door control,
Inspection 1. Turn the ignition switch OFF. 2. Disconnect the console temperature control actuator connector. 3. Verify that the console temperature control actuator operates to the defrost mode when connecting 12V to terminal 3 and grounding terminal 4.