Hyundai Genesis (DH): Airbag Module / Side Airbag (SAB) Module Repair procedures

Hyundai Genesis (DH) 2013-2016 Service Manual / Restraint / Airbag Module / Side Airbag (SAB) Module Repair procedures

Removal
Front Side Airbag
1.
Disconnect the battery negative cable and wait for at least 3 minutes before beginning work.
2.
Remove the front seat assembly.
(Refer to Body - "Front Seat Assembly")
3.
Remove the seat back cover.
(Refer to Body - "Front Seat Back Cover")
   
When the front side airbag has deployed after a collision, replace the seat back as an assembly.
4.
Loosen the SAB mounting nuts and remove the SAB module.

   
The removed airbag module should be stored in a clean and dry place with the cushion side up.
Rear Side Airbag
1.
Disconnect the battery negative cable and wait for at least 3 minutes before beginning work.
2.
Remove the rear seat assembly.
(Refer to Body -"Rear Seat Assembly")
3.
Loosen the rear side seat back mounting bolt (2EA).
4.
Disconnect the rear side airbag assembly connector, and then remove the rear side seat back.

5.
Remove the rear side airbag assembly cover.
   
When the rear side airbag has deployed after a collision, replace the rear side seat back as an assembly.
6.
Loosen the rear side airbag module mounting nuts and remove the airbag module.
   
The removed airbag module should be stored in a clean and dry place with the cushion side up.

Installation
Front Side Airbag
   
Be sure to install the harness wires so they will not pinch or interfere with other parts.
   

    Description Curtain airbags are installed inside the headliner (LH and RH) and protect the driver and passenger from danger when a side crash occurs.

    Other information:

    Hyundai Genesis (DH) 2013-2016 Service Manual: In-car Sensor Repair procedures

    I

    Hyundai Genesis (DH) 2013-2016 Service Manual: Auto Defogging Actuator Repair procedures

    Inspection 1. Turn the ignition switch OFF. 2. Disconnect the auto defogging connector. 3. Verify that the auto defogging actuator operates to the open position when connecting 12V to terminal 3 and grounding terminal 4. Verify that the auto defogging actuator operates to the close position when connected in reverse.

    Categories

     
    Copyright В© 2026 www.hgenesisdh.com - 0.0231