| Removal and Installation |
| 1. |
Disconnect the battery "-" terminal from the trunk room. |
| 2. |
Remove the engine cover.
(Refer to Engine And Transaxle Assembly - "Engine Cover") |
| 3. |
Remove the VIS actuator (A).
|
| 4. |
To install, reverse the removal procedure. |
Removal and Installation [Air Cleaner Assembly] 1. Disconnect the battery "-" terminal from the trunk room. 2. Remove the engine cover. (Refer to Engine And Transaxle Assembly - "Engine Cover") 3.
Components 1. Surge tank2. VIS actuator
Removal 1. Disconnect the negative (-) battery terminal. 2. After loosening the nuts (4EA) holding the rear combination lamp and disconnecting the connector (A), remove the outside rear combination lamp assembly. 3. Remove the bulb (A) after turning it in the counter clock-wise direction.
Instructions When Handling Refrigerant 1. R-134a liquid refrigerant is highly volatile. A drop on the skin of your hand could result in localized frostbite. When handling the refrigerant, be sure to wear gloves. 2. It is standard practice to wear goggles or glasses to protect your eyes, and gloves to protect your hands.