| Specification |
| Item | Specification | |
| Rated voltage | 12 V, 1.7 kW | |
| The number of pinion teeth | 12 | |
| Performance [No-load, 11.5 V] | Ampere | Max. 105 A |
| Speed | Min. 2,550 rpm | |
Description The starting system includes the battery, starter, solenoid switch, ignition switch, inhibitor switch (A/T), clutch pedal switch (M/T), ignition lock switch, connection wires and the battery cable.
Components 1. Front bracket2. Planet gear shaft assembly3. Lever4. Lever packing5. Magnet switch6. Planet gear7. Shield8. Armature assembly9. York assembly10.
Inspection 1. Turn the ignition switch OFF. 2. Disconnect the mode control actuator connector. 3. Verify that the mode control actuator operates to the defrost mode when connecting 12V to terminal 3 and grounding terminal 4. Verify that the mode control actuator operates to the vent mode when connected in reverse.
R