| Specification |
| Item | Specification |
| Ultrasonic sensor | Voltage rating | DC 12 V |
| Detecting range | 40 cm ~ 120 cm |
| Operation voltage | DC 9 ~ 16 V |
| Operation current | MAX 300 mA |
| Operation temperature | -30 |
Component Location 1. BCM (Body Control Module)2. Ultrasonic sensor Rear parking assist control unit function is built in BCM (body control unit).
Description The ambient temperature sensor is located inside the side mirror and detects ambient air temperature. It is a negative type thermistor; resistance will increase with lower temperature, and decrease with higher temperature. The sensor output will be used for discharge temperature control, temperature regulation door control,
Inspection 1. Turn the ignition switch ON. 2. Manually operate the control switch and control the voltage of the blower motor. 3. Select the control switch to raise the voltage until high speed. Specification Fan Speed (Manual)Motor Voltage (V)13.