| Specification |
| Item | Specification |
| Ultrasonic sensor | Voltage rating | DC 12 V |
| Detecting range | 40 cm ~ 120 cm |
| Operation voltage | DC 9 ~ 16 V |
| Operation current | MAX 300 mA |
| Operation temperature | -30 |
Component Location 1. BCM (Body Control Module)2. Ultrasonic sensor Rear parking assist control unit function is built in BCM (body control unit).
C
Inspection 1. Turn the ignition switch OFF. 2. Disconnect the mode control actuator connector. 3. Verify that the mode control actuator operates to the defrost mode when connecting 12V to terminal 3 and grounding terminal 4. Verify that the mode control actuator operates to the vent mode when connected in reverse.