| Removal |
| 1. |
Remove the console upper cover (A). |
| 2. |
Pull the shift lever knob (B) upward to remove it.
|
| 3. |
Remove the knob&boots(A) from the console upper cover.
|
| 4. |
Remove the floor console.
(Refer to Body - "Floor Console") |
| 5. |
Disconnect the connector (A) from the shift lever.
|
| 6. |
Disconnect the shift cable (A) from the shift lever.
|
| 7. |
Remove the shift lever assembly (A) by removing the four bolts.
|
| Installation |
| 1. |
To install, reverse the removal procedure. |
Components 1. Shift lever knob2. Shift lever boots3. Shift lever assembly4. Shift cable
Components 1. Shift lever knob2. Shift lever boots3. Shift lever assembly4. Shift cable
C
Instructions When Handling Refrigerant 1. R-134a liquid refrigerant is highly volatile. A drop on the skin of your hand could result in localized frostbite. When handling the refrigerant, be sure to wear gloves. 2. It is standard practice to wear goggles or glasses to protect your eyes, and gloves to protect your hands.