| Description |
Never attempt to measure the circuit resistance of the airbag
module (squib) even if you are using a specified tester. If the circuit
resistance is measured with a tester, accidental airbag deployment will
result in serious personal injury. |
Removal 1. Disconnect the battery negative cable and wait for at least 3 minutes before beginning work. 2. Remove the roof trim assembly. (Refer to Body - "Roof Trim Assembly") 3.
Inspection 1. Connect the battery voltage and check the blower motor rotation. 2. If the blower motor does not operate well, replace it with a genuine blower motor check for proper operation. 3. Replace the blower motor if it is proved that there is a problem with it.
Inspection 1. Turn the ignition switch OFF. 2. Disconnect the intake actuator connector. 3. Verify that the intake actuator operates to the fresh position when connecting 12V to terminal 3 and grounding terminal 4. Verify that the intake actuator operates to the recirculation position when connected in reverse.