| Specifications |
| Items | Performance spec | |||
| MAX, load current consumption (12V) | 23.3 + 10% A | |||
| Input | Communication frequency | 300 | ||
Description The cooling fan controlsx the cooling fan motor voltage depending on the duty output from the ECU (Freq.: 300Hz). [Signal from the ECU to the PWM (SI: 300Hz)] SI DutyMotor Voltage (V)Variation (V)10%0
Cooling Circuit Diagram
Inspection 1. Turn the ignition switch OFF. 2. Disconnect the mode control actuator connector. 3. Verify that the mode control actuator operates to the defrost mode when connecting 12V to terminal 3 and grounding terminal 4. Verify that the mode control actuator operates to the vent mode when connected in reverse.
Inspection 1. Turn the ignition switch OFF. 2. Disconnect the console temperature control actuator connector. 3. Verify that the console temperature control actuator operates to the defrost mode when connecting 12V to terminal 3 and grounding terminal 4.