Hyundai Genesis (DH): Air Conditioning System / Ambient Temperature Sensor Repair procedures

Inspection
1.
Check the resistance of the ambient temperature sensor between terminals 1 and 2 whether it changes by changing the ambient temperature.

1. Ambient Sensor (+)

2. Sensor ground

Specification
Ambient temperature
[

    Description The ambient temperature sensor is located inside the side mirror and detects ambient air temperature. It is a negative type thermistor; resistance will increase with lower temperature, and decrease with higher temperature.

    Description This system maintains the density of carbon dioxide constantly in vehicle interior by measuring the amount of carbon dioxide to increase the comfortableness and the fuel consumption rate when air conditioning system is operating.

    Other information:

    Hyundai Genesis (DH) 2013-2016 Service Manual: Components and Components Location

    C

    Hyundai Genesis (DH) 2013-2016 Service Manual: Auto Defogging Actuator Repair procedures

    Inspection 1. Turn the ignition switch OFF. 2. Disconnect the auto defogging connector. 3. Verify that the auto defogging actuator operates to the open position when connecting 12V to terminal 3 and grounding terminal 4. Verify that the auto defogging actuator operates to the close position when connected in reverse.

    Categories

     