| Specifications |
| Control Pressure kpa (kgf/cm?, psi) | 0~500.14 (0~5.1,0~72.54) |
| Current value(mA) | 0~850 |
| Internal resistance(?) | 4.8~5.4 |
Description Line pressure control solenoid valve is attached to the valve body. This variable force solenoid valve directly controls the hydraulic presssure inside the line presure .
Circuit Diagram
Inspection 1. Turn the ignition switch OFF. 2. Disconnect the mode control actuator connector. 3. Verify that the mode control actuator operates to the defrost mode when connecting 12V to terminal 3 and grounding terminal 4. Verify that the mode control actuator operates to the vent mode when connected in reverse.
Inspection 1. Turn the ignition switch OFF. 2. Disconnect the auto defogging connector. 3. Verify that the auto defogging actuator operates to the open position when connecting 12V to terminal 3 and grounding terminal 4. Verify that the auto defogging actuator operates to the close position when connected in reverse.