| Description |

Inspection 1. Connect the GDS on the Data Link Connector (DLC). 2. If there is DTC on the GDS, replace the FPCM. 3. Check the output voltage of fuel pressure sensor (FPS).
Specification Pressure(kPa)Output Voltage(V)500.36002.511004.5
D
Description The ambient temperature sensor is located inside the side mirror and detects ambient air temperature. It is a negative type thermistor; resistance will increase with lower temperature, and decrease with higher temperature. The sensor output will be used for discharge temperature control, temperature regulation door control,