Removal 1. Disconnect the vapor hose (A). 2. Remove the rubber pad (B), and then remove the PCV valve. Inspection 1. Insert a thin stick (A) into the PCV valve (B) of the threaded side to check that the plunger moves.
Schematic Diagram
Removal 1. Disconnect the negative (-) battery terminal. 2. Remove the glove box housing (A). (Refer to Body - "Glove Box") 3. Remove the PGS unit (A) after loosening the nuts. Installation 1. Install the PGS unit. 2. Install the glove box housing.
Inspection 1. Turn the ignition switch OFF. 2. Disconnect the auto defogging connector. 3. Verify that the auto defogging actuator operates to the open position when connecting 12V to terminal 3 and grounding terminal 4. Verify that the auto defogging actuator operates to the close position when connected in reverse.