| Specifications |
| Control Pressure kpa (kgf/cm?, psi) | 0~2108.42 (0~21.5~305.80) |
| Current value(mA) | 0~1100 |
| Internal resistance(?) | 5.0~5.6 |
Description 8LR Brake control solenoid valve is attached to the valve body. This variable force solenoid valve directly controls the hydraulic pressure inside the 8LR Brake.
Circuit Diagram
Description The auto defogging sensor is installed on the front window glass. The sensor judges and sends signal if moisture occurs to blow out wind for defogging. The air conditioner control module receives signal from the sensor and restrains moisture and eliminate defog by controlling the intake actuator, A/C, auto defogging actuator,
Inspection 1. Turn the ignition switch OFF. 2. Disconnect the console temperature control actuator connector. 3. Verify that the console temperature control actuator operates to the defrost mode when connecting 12V to terminal 3 and grounding terminal 4.