Hyundai Genesis: Automatic Transmission Control System / Line Pressure Control Solenoid Valve Description and Operation
Line pressure control solenoid valve is attached to the valve
body. This variable force solenoid valve directly controls the
hydraulic presssure inside the line presure .

Inspection
1.
Turn ignition switch OFF.
2.
Disconnect the E Module connector.
3.
Measure resistance between solenoid valve terminals.
4.
Check that the resistance is within the spec ...
Specifications
Line Pressure Control VFS
? Control type : Normal high type
Control Pressure kpa (kgf/cm?, psi)0~500.14 (0~5.1,0~72.54)Current value(mA)0~850 Internal resistance ...
Other information:
Description
The Tilt & Telescope operation function in SCM contains of the following function.
1.
Manual control with direction switches (Tilt Up/Down, Telescope Forward/Backward).
2.
Playback with position switches (P1 and P2 switches).
3.
Memory with position switches (P1 and P2 s ...
Inspection
1.
Turn the ignition switch OFF.
2.
Disconnect the PCSV connector.
3.
Measure resistance between the PCSV terminals 1 and 2.
4.
Check that the resistance is within the specification.
Specification: Refer to “Specification”
Removal
1.
Turn the ignition switc ...