| Inspection |
| 1. |
Check signal waveform of Input speed sensor using the GDS.
|
Circuit Diagram
Description Middle speed sensor is a vital unit that measures the direction of rotation of the input shaft inside the transmission and delivers the readings to the TCM.
Instructions When Handling Refrigerant 1. R-134a liquid refrigerant is highly volatile. A drop on the skin of your hand could result in localized frostbite. When handling the refrigerant, be sure to wear gloves. 2. It is standard practice to wear goggles or glasses to protect your eyes, and gloves to protect your hands.
Description The auto defogging sensor is installed on the front window glass. The sensor judges and sends signal if moisture occurs to blow out wind for defogging. The air conditioner control module receives signal from the sensor and restrains moisture and eliminate defog by controlling the intake actuator, A/C, auto defogging actuator,