Hyundai Genesis (DH): Air Conditioning System / Refrigerant Line Repair procedures

Replacement
1.
Discharge refrigerant from refrigeration system.
2.
Replace any faulty tubes or hoses.
   
Cap the open fittings immediately to keep moisture or dirt out of the system.
3.
Tighten the bolt or nut joint to the specified torque.
   
The torque for the connections should not be tighter than the specified torque.
4.
Evacuate air from the refrigeration system and charge the system with refrigerant.

Specified amount:
700

    Oil Specification 1. The HFC-134a system requires synthetic (PAG) compressor oil whereas the R-12 system requires mineral compressor oil. The two oils must never be mixed.

    Description The compressor is the power unit of the A/C system. It is located on the side of engine block and driven by a V-belt of the engine. The compressor changes low-pressure and low-temperature refrigerant gas into high-pressure and high-temperature refrigerant gas.

    Other information:

    Hyundai Genesis (DH) 2013-2016 Service Manual: Components and Components Location

    S

    Hyundai Genesis (DH) 2013-2016 Service Manual: A/C Pressure Transducer Description and Operation

    Description The A/C Pressure Transducer (APT) converts the pressure value of high-pressure line into voltage value after measuring it. By converted voltage value, engine ECU controls the cooling fan by operating it at high speed or low speed.