Hyundai Genesis (DH): Windshield Wiper/Washer / Rain Sensor Repair procedures

Removal
   
The dust or foreign substance on the rain sensor has a bad effect upon the rain sensor capability, so protect the sensor surface with protection cover until installing the rain sensor to bracket for accurate function
The coupling pad on the rain sensor surface has adhesive strength, so the coupling pad could stick to the windshield by environment condition during the using time.
If the rain sensor is removed by force, it could be damaged. So make sure to separate the rain sensor from the windshield carefully.
1.
Remove the mirror wiring cover (A) and rain sensor cover (B).

2.
Disconnect the rain sensor connector (A).

3.
Be careful not to damage the cover latch by applying excessive force. To remove the bracket, pull the holes of the bracket outside using a small flat-head screwdriver.

4.
Rain sensor module is attached to the front windshield by glue. When replacing the front windshield, remove the rains sensor module form the existing front windshield and install it on the new front windshield.
Installation
   

    Description Integrated Rain Sensor Integrated rain sensor (A) controls three systems: front wiper, auto-light, and central air conditioner. 1. Wiper Control System When "AUTO" switch signal is received from the multi-function switch on the right, the integrated rain sensor detects the amount of rainfall.

    Other information:

    Hyundai Genesis (DH) 2013-2016 Service Manual: Auto Light Sensor Repair procedures

    Removal 1. Disconnect the negative (-) battery terminal. 2. Remove the photo & auto light sensor. (Refer to Windshield Wiper/Washer - "Rain Sensor") Installation 1. Install the auto light sensor. 2. Connect the negative (-) battery terminal.

    Hyundai Genesis (DH) 2013-2016 Service Manual: Console Temperature Control Actuator Repair procedures

    Inspection 1. Turn the ignition switch OFF. 2. Disconnect the console temperature control actuator connector. 3. Verify that the console temperature control actuator operates to the defrost mode when connecting 12V to terminal 3 and grounding terminal 4.

    Categories

     