Hyundai Genesis (DH): Engine Control System / CVVT Oil Temperature Sensor (OTS) Repair procedures

Inspection
1.
Turn the ignition switch OFF.
2.
Disconnect the OTS connector.
3.
Remove the OTS (Refer to "Removal").
4.
After immersing the thermistor of the sensor into engine coolant, measure resistance between the OTS terminals 1 and 2.
5.
Check that the resistance is within the specification.

Specification: Refer to

    Description Continuous Variable Valve Timing (CVVT) system advances or retards the valve timing of the intake and exhaust valve in accordance with the ECM control signal which is calculated by the engine speed and load.

    Other information:

    Hyundai Genesis (DH) 2013-2016 Service Manual: Troubleshooting

    Troubleshooting Problem Symptoms Table Before replacing or repairing air conditioning components, first determine if the malfunction is due to the refrigerant charge, air flow or compressor. Use the table below to help you find the cause of the problem.

    Hyundai Genesis (DH) 2013-2016 Service Manual: Ambient Temperature Sensor Description and Operation

    Description The ambient temperature sensor is located inside the side mirror and detects ambient air temperature. It is a negative type thermistor; resistance will increase with lower temperature, and decrease with higher temperature. The sensor output will be used for discharge temperature control, temperature regulation door control,