Inspection Steering Wheel Remote Control system (SWRC) can be diagnosed by GDS because it receives and sends signals through CAN communication.
Inspection Glass Antenna Test 1. Wrap aluminum foil (A) around the tip of the tester probe (B) and move the probe along the grid line to check whether the circuit opens.
Instructions When Handling Refrigerant 1. R-134a liquid refrigerant is highly volatile. A drop on the skin of your hand could result in localized frostbite. When handling the refrigerant, be sure to wear gloves. 2. It is standard practice to wear goggles or glasses to protect your eyes, and gloves to protect your hands.
Replacement 1. Remove both stoppers (B) by turning them from the glove box (A). 2. Disconnect the air damper (A) from the glove box (B). 3. Remove the filter cover (A) by pressing the knob. 4. Replace the air filter (A) with a new one according to the direction of air filter.